From surface heating to full surface heating

To increase the coefficient of performance of the heat pump, every degree less flow temperature counts. We take this to the extreme with full-surface heating!






From surface heating to full surface heating
To increase the coefficient of performance of the heat pump, every degree less flow temperature counts. We take this to the extreme with full-surface heating!

  Reduce electricity demand for room heating and cooling


The possibilities with better thermal insulation and heat recovery from exhaust air have been used up. What remains as an optimization is to increase the coefficient of performance of the heat pump. The lower the temperature difference, the better. Low-temperature heat storage and producing heat from the air only during the warmest hours of the day, skipping cold spells, is one part of the strategy.

The other part of the strategy is lowering supply temperature by adding more heating surfaces. From radiators to optimized radiators, on to floor heating. Still further to the combination of wall heating and underfloor heating. But even that can be increased with full-surface heating.

  20° room temperature, 21° supply temperature


Here are examples of how different flow temperatures affect the coefficient of performance of the heat pump. A 2° warm heat source and 40% of the theoretically maximum achievable coefficient of performance according to Carnot are assumed.

Supply temperature 60° 50° 40° 35° 30° 27° 24° 21°
Coefficient Of Performance 2.30 2.69 3.30 3.74 4.33 4.80 5.40 6.19
Electricity for 1200 kWh heat 522 446 364 321 277 250 222 194

  Wall and floor are almost 2,000 liters of buffer storage


In a conventional setup, 10 m of heating pipe per m² of wall is common. With 16 mm aluminum composite pipe with 12 mm inner diameter, this is 1.13 liters of water per m² wall. Our last wall construction before the invention of full-surface heating in August 2022 therefore also only had a heat storage capacity of 14.9 kJ/m²/K, which is relevant for the interior. With the new wall construction with full-surface heating, this increased to almost 14 liters of water per m² of wall and 75 kJ/m²/K.

Technology in GEMINI next Generation House
For some, technical innovation is a great exciting adventure, for others incomprehensible boredom. This page is written only for the some.


Electricity surplus: The power grid is only there to sell electricity Electricity surplus: The power grid is only there to sell electricity
On-grid and off-grid with identical GEMINI next generation houses. Off-grid is only more difficult to finance because the income from electricity sales is missing.


Significantly more efficiency with heat pumps Significantly more efficiency with heat pumps
You can sell more electricity if you need less yourself. Therefore, 3 innovations at once for the utmost efficiency in space heating, space cooling and hot water.


Ventilation with heat and moisture recovery from exhaust air Ventilation with heat and moisture recovery from exhaust air
We do not take just any ventilation system, but one with moisture and heat recovery from exhaust air and 20 cm pipes for extremely quiet and economical operation.


Wall construction with the top specialists for each task Wall construction with the top specialists for each task
The tasks of a wall are statics, thermal insulation, noise insulation and heat storage. We use a top specialist for each of these tasks.






          From surface heating to full surface heating: To increase the coefficient of performance of the heat pump, every degree less flow temperature counts. We take this to the extreme with full-surface heating! https://technology.gemini-next-generation.house/surface-area-heating/